Standard Components

Explore Pro Amplifier

Compact, lightweight EEG/ExG amplifier with integrated battery, memory, and IMU.

Protective Case

Shock-resistant carrying and storage case to keep the device safe during transport.

EEG Cap

One elastic EEG cap in the chosen size, preconfigured for use with dry or gel electrodes.

Electrodes

Depending on configuration: Dry electrodes (spring-loaded or flat types) for quick setup. Gel-based electrodes for lower impedance, supplied with lead wires. Reference electrode.

USB-C Cable

Use the USB-C cable to charge the amplifier, transfer data, or operate the amplifier in tethered mode.

USB Streaming Isolator (UI)

The USB Streaming Isolator (UI) provides safe, interference-free data transmission between the amplifier and a host computer.

The isolator is enclosed in a heat-dissipating mesh and must be used together with the supplied 11.5 cm extension cable.

Before using the device, read and observe all operating instructions and safety warnings provided below.

Using the USB Streaming Isolator in a Body-Worn Configuration

When operating the amplifier in wired mode, the USB Streaming Isolator must be installed between the body-worn amplifier and the host computer or charger.

  1. Connect the USB Streaming Isolator to the supplied 11.5 cm extension cable.

USB Streaming Isolator connected to the extension cable
Connecting the USB Streaming Isolator
  1. Connect the other end of the extension cable to the amplifier. The extension cable must remain positioned between the amplifier and the USB Streaming Isolator.

  2. Connect the long USB-C cable to the opposite side of the USB Streaming Isolator.

  3. Connect the other end of the USB-C cable to the host computer or charger.

Body worn use of the UI dongle, in wired mode
Body worn use of the UI dongle, in wired mode

Always use the provided USB isolator (UI) and provided distance cable when charging or connecting the amplifier via cable while wearing it.

SAFETY NOTICE - OPERATING TEMPERATURE OF THE UI DONGLE

The UI dongle may become warm during normal operation. This does not indicate a malfunction.

Use the UI dongle only at room temperature. Keep the device exposed to air and do not cover, wrap, or wear it under clothing or insulating materials.

For head-worn recording setups, use the supplied distance cable and 3D mesh as specified to reduce direct skin contact and to keep the UI dongle separated from the skin.

Special care is required around children and persons with reduced sensitivity to heat. Stop use if the device feels uncomfortably warm or if skin irritation occurs.

EEG Starter Set

Contains gel, syringe, cleaning solution, and brush.